2.3.2 E1/T1 Status
Figure 2-3-2 E1/T1 Status
Table 2-3-2 Description of E1/T1 status
1. LOS Alarm: Signal loss alarm, this alarm is created when receiving is lost; please check
the physical connection whether disconnected.
2. RAI Alarm: Receive remote alarm indication, it is a signal transmitted in the outgoing
direction when a terminal determines that it has lost the incoming signal. Receiving
remote alarm indication (RAI) means the far-end equipment over the T1 line has a
problem with the signal it is receiving from the upstream equipment.
3. AIS Alarm: The Alarm Indication Signal (AIS) failure is declared when an AIS defect is
detected at the input and the AIS defect still exists after the Loss of frame failure which is
caused by the unframed nature of the 'all-ones' signal is declared. The AIS failure is
cleared when the Loss Of Frame failure is cleared.
4. Disable: Means that this E1/T1 is not used.
5. ISDN/SS7 Signal Alarm: Means physical connection is normal, signaling link has
problem.
6. Active-OK: Means that physical connection and signaling link are normal.
Frame-Sync: Non voice channel, which used as a synchronization channel
Idle: Means this channel is idle, when the channel is enabled and the cable is connected
OK.
4.Busy: Means this channel is occupied by voice
5. Fault: The channel is enabled but the cable is not connected.
6.Disable: Have not use this E1/T1 trunk
Local blocked, means that communication can only be initiated from local